Comfort Experts Annual Tune-up

Excellent Service! Ian, the Technician was excellent and possessed technical skills and communication skills!

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

He knew what needed to be done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great customer service .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Good job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Mark went above and beyond to ensure our new dryer worked.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Tyler arrived to inspect my home's electrical as part of my membership benefit. He was friendly, knowledgeable and did a great job explaining everything and fixed a couple of small issues that I had going on.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tech was cool.

Justin, he arrived and accomplished what he was supposed to do, and in a timely manner.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for springtown, tx

Justin  P.

Justin P. Job Checkin

2017 Lennox airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Blower cap was within manufacture range Evaporator coil was acceptable Some biological growth on condensate pan 2017 Lennox straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit 2018 mini split Checked and tightened all electrical connections Washed filters Evaporator coil was heavily compacted with dust dirt and biological growth Blower wheel was heavily compacted with dust dirt and biological growth Checked and tightened all outdoor connections Washed Condenser coil Waxed too of unit Recomme


Mark D.

Mark D. Job Checkin

Goodman propane furnace with straight cool condenser. All electrical connections are tight with no corrosion. Inducer motor, gas pressure, igniter and heat exchanger are all acceptable. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range.


Ian C.

Ian C. Job Checkin

Upon arrival the battery's in the thermostat was dead the system was turned off. Replaced customer supplied battery's. Turned system to cooling and made sure that system was working properly and the refrigerant levels where good. While inspection of the attic I located exposed wires need to be put in a junction box, this is a fire hazard, also found on cust panel it is exposed and someone could easily be shocked, going to put covers on panel. Cust has florescent lights outside that are burnt out, cust wants Me to change bulbs, explained to cust that we will likely have to change the fixtures due to them being old and not having secure connections. Wants to try changing bulbs first if this doesn't work we will change fixtures. Need to return first call Thursday the 25th I will gather parts


Lisa M.

Lisa M. Job Checkin

Completed annual air conditioning tune up.


Justin  P.

Justin P. Job Checkin

Upon arrival Customer stated system would not come on day prior to visit. After evaluation found system tripped on high-pressure, Customer ran system yesterday in Heat mode with outdoor temperature of 70 plus causing high pressure and causing compressor to trip


Justin  P.

Justin P. Job Checkin

2019 Goodman gas furnace Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable 2019 Goodman straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended pan treatment, uv system, compressor saver and HBPPlan


Mike  S.

Mike S. Job Checkin

Schrader valve was leaking as soon as I pulled the cap. Barely any pressure in the system sold 16 Oz of 410a and got it cooling.


cody.brooks@acgenius.com

cody.brooks@acgenius.com Job Checkin

04/17/24 Techs Cody and Hunter arrived to customer's home. We met Mr.Aroz and he guided us inside to the thermostat and attic access. Cody started inside at the indoor unit and immediately noticed corrosion in the drain pan and microbial growth in the blower cabinet. The coil was clean and had no corrosion, the filter was not in need of replacement. Outside Hunter cleaned the coil and found a failed contactor inside the electrical box due to a loose connection. The homeowner had a lifetime warranty on the part so we replaced it free of charge. Once we got the system running we hooked up the guages and found the system to be overcharged. I do not have a recovery drum on my truck so I was unable to remove refrigerant from the system. I called dispatch to let them know about the situation and had to pause the call.


cody.brooks@acgenius.com

cody.brooks@acgenius.com Job Checkin

Techs Cody and Hunter arrived to customer's home. Hunter went to the thermostats and it is in emergency heat mode we switched it cooling. It started to cool. We hooked up to the condenser and the subcool was in -3 and stayed there. The unit was a piston. We assume there is a leak somewhere. The house was at the temperature they liked so they didn't want us to look for a leak.


Derek.bryant@acgenius.com

Derek.bryant@acgenius.com Job Checkin

Water heater in barn had bad egg smell, flushed heater. Told customer if it continues we will have to get a electric anode rod in the tank


Justin  P.

Justin P. Job Checkin

Upon arrival Customer stated that system froze up the day before. Water heater next to airhandler leaked water. Home owner took panels off airhandler to see if ac was causing leak and found water heater was the issue. While having Blower door off the coil started to freeze. Checked all electrical for water damage, found no damage. Checked Refrigerant levels and Refrigerant levels were acceptable at this time. Delta T was acceptable, house was at 70 ran system for 15 minutes and house temp dropped to 66. System is functional and working properly at this time. Left system in cool Customer confirmed


Mark D.

Mark D. Job Checkin

Amana heat pump with air handler installed in 2018. All electrical connections are tight with no corrosion. X13 blower motor is acceptable. Blower wheel and evaporator coil are clean. 45/5 dual run capacitor was out of tolerance and was replaced on this visit. Refrigerant levels are in range. Compressor and condenser fan motor are acceptable. System running as it should at this time. 45/5 dual run capacitor and germicidal UV bulb were both replaced on this visit.


mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

2019 airhandler Checked and tightened all electrical connections Customer did not have extra filter Drain was clear and draining Blower motor and wheel were compacted with dust and dirt Evaporator coil was acceptable Heat strips were functional and within manufacture range 2019 Rheem straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended pan treatment, blower cleaning and unit surge protection


Alex  D.

Alex D. Job Checkin

Installed 2-10” returns in bedrooms 1 and 2 in bedroom two we put the return were the supply for the room originally was and moved the supply to the exterior wall pointing to the interior wall per dons request also installed 1-16” return in master hallway ran the new returns to a main duct board box and ran an 18” return duct to plenum


Ian C.

Ian C. Job Checkin

Cb on me fixed issue