Jake was extremely amazing he's very knowledgeable let me know everything about the job He answer all my questions thank you Jake
Once again great service from Mark W (and Zack W). Had to replace a water heater. Same day service, easy installation with no hassles and a job well done. Work was excellent and they left the job site cleaner then they found it. I’ll never use anyone else for my plumbing needs.
Jonathon completed required service assessment in timely manner. Looks like complete report.
He diagnosed problems and replaced the necessary parts while providing explanations. Got the system running again!
Knowledgeable young man. Got us back up with heat and hot water until a permanent fix can be done. Hopefully soon. Thanks
Service by Colby today. Checked the HVAC system. Fixed a couple minor issues. Now I know I’m good to go for Fall, Winter and into Spring. He did a great job. Always pleased with Comfort Air.
This man was so patient with our issue getting someone to the house so he could do his work and gave me prompt feedback on what he did. Excellent person.
Justin did a great job and took very good care of us! Let us know what the problem was right away.
I have completed my electrical tune-up the panel looks great it's a newer square d they do have solar as well but no surge protection and they are having trouble with two outlets in the kikitchenhat I did briefly look at but further inspection would require a diagnostic
Installed compressor Tested system holding pressures System refrigerant is at manufacturer specifications System left on cool at exit
For this evaluation the customers upstairs units had stopped cooling because the primary drain line was clogged and the float switch was tripped. Due to us being out here earlier in the month I went ahead and cleared the drain line since the customer had plumbing work done and it appeared that the drain line was clogged because where the sink drain meets the p-trap and condensate drain line connection is obstructing the drain hole and not allowing it to drain properly
Install 36k heat pump horizontal with high efficiency media filtration, duct cleaning and code kit
Performed evaluation Upon arrival outdoor system compressor was not functional - Fan was operational All other cooling components are in tolerance High voltage is good Compressor has failed mechanically Unable to operate pulling LRA 198 Tested wires and cap head to compressor - functional Compressor has not overheated during evaluation Tested functionality with Hard start - 0 performance Trane compressor warranty Model# 4TTR6030J1000BA Serial # 22364G4D5F Recommended Soft start kits Recommended home and budget protection plan Condenser switch left off - indoor unit fan run only
Gave estimates for wh customer is on vacation his neighbor will call to let us to move forward with work if okd
Arrived for service eval System running on arrival Capacitor and running amp draw are fine Refrigerant levels are fine and delta is 18 degrees Compressor exceeding LRA and drain lines may not be completely clear from previous plumbing line work Added pan strips to both systems to clean drain lines and a start kit to the condenser to help the compressor start
Arrived for rec work Resealed slit ductwork Reattached two ducts Resealed plenum System of at thermostat when I left
Arrived for coil replacement Replaced coil Pressure and decay test passed Refilled refrigerant. System cooling with a superheat of 27 on exit
Wife was the only one home for appointment will relay everything to her husband later this evening quoted a 36k zone system
Technician arrived to customers home, asked questions about problem, homeowner mentioned it wasn't cooling she thinks since Saturday. Technician inspected attic unit, everything seemd in good condition, technician continued to outside unit, refrigerant levels low, did a leak search on attic unit and condenser unit, no success on finding leaks. Technician added refrigerant to ratings. System cooling no problems not cooling. Technician talked to customer about problems. Unit cooling upon departure
Arrived for IAQ estimate Ducts are cut in 5 places and one duct needs to be trimmed back and reattached Homeowner opted for sealing the slide ducts instead of replacing them Added duct/plenum seal to the insulation estimate Homeowner will discuss with his wife and get back to us
For this job I performed a evaluation. Upon arrival the first thing that I checked was the indoor unit and the Attic. I quickly noticed that the emergency drain pan had water in it which made me assume either they had a coil freeze with low refrigerant or there was a clock in the primary drain line. I tested the drain line and it was clear. When turning on the system the coils began to freeze, I like search the evaporator coil and quickly found a leak. Homeowner was still under manufacturers warranty so I recommended replacing the evaporator coil. Holding for parts, will reschedule when the evaporator coil comes in. Customer paid for the new coil.