1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for haslet, tx

Rated 4.9 out of 5 stars based on 73 customer reviews

Thanks Jake!

Great service with Jake today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Jake came out on one of the coldest day last winter. He replaced a whole breaker box. Fast forward to today and we had a problem in the breaker box and he came out and fixed it in a matter of minutes. Very talented and very respectful. Thank you Jake.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceptionally well executed

Jake was extremely amazing he's very knowledgeable let me know everything about the job He answer all my questions thank you Jake

  • Overall Experience
  • Quality
  • Price
  • Convenience

New Water Heater

Once again great service from Mark W (and Zack W). Had to replace a water heater. Same day service, easy installation with no hassles and a job well done. Work was excellent and they left the job site cleaner then they found it. I’ll never use anyone else for my plumbing needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and complete service

Jonathon completed required service assessment in timely manner. Looks like complete report.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

He diagnosed problems and replaced the necessary parts while providing explanations. Got the system running again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Knowledgeable young man. Got us back up with heat and hot water until a permanent fix can be done. Hopefully soon. Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Professional and pleasant to work with. Great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job by Colby

Service by Colby today. Checked the HVAC system. Fixed a couple minor issues. Now I know I’m good to go for Fall, Winter and into Spring. He did a great job. Always pleased with Comfort Air.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Jose Govea

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

This man was so patient with our issue getting someone to the house so he could do his work and gave me prompt feedback on what he did. Excellent person.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service and Experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Servuce

Justin did a great job and took very good care of us! Let us know what the problem was right away.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Review

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for haslet, tx

Mike R.

Mike R. Job Checkin

On this visit I replaced a 40 cap and got rid of the hard start and added a new easy start


Mike R.

Mike R. Job Checkin

On this visit I looked at both heating and cooling of the system. I'm happy to report that they both test in tolerance. The td 20°. The filter is new and condensor is washed. Concerns High LRA 77 The system could benfit from easy start management system. This will reduce the in rush bye 75% give it added longevity and better job performance.


Jake  S.

Jake S. Job Checkin

Came to job for GFCI tripping every now and then when storms happen and talk to customer about it and replaced plug giving issues


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

For this evaluation I inspected the customer's furnace and condenser. Overall everything looked good and all equipment was measuring within manufacturer specifications. I took a look at the customer's water heater as well as the electrical panel, when I took the plate off of the electrical panel the entire left side of the panel and breakers we're running extremely hot at approximately 130° f or 54° c. The rating for those breakers was 40°c indicating those breakers are running extremely hot however they are not tripping. This is a potential fire hazard as well as safety issue which I would highly recommend getting inspected which I offered a free referral for an electrician however the customers may want to go with an independent contractor. To get ahead of any potential issues I did recommend installing a whole home surge protector as well as a hard start kit for the compressor to prevent the compressor from overamping on startup and potential damage that could cause.


toby.turner@acgenius.com

toby.turner@acgenius.com Job Checkin

Level 3 48k gas horizontal $18,500


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

For this evaluation, the customers primary drain line had come loose at one of the joints. My best guess is that while I was working yesterday, I either stepped on the primary drain line or bumped it, causing that glue that was holding the PVC into the joint to come loose, and the water was dripping out of the primary drain line into the ceiling. I gave my sincere apologies to the customer and filled out a home damage report and let RYAN know what had happened.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

For this cooling tune-up I inspected the customers air handler and condenser. For the most part all equipment was measuring within manufactured specs and running well. The compressor was over ramping on startup with a maximum lra of 152 amps however the compressor was pulling 160 amps on startup. I recommend it to the customer that we install a hard start kit to the compressor to keep the amp draw on startup below the manufacturer specifications. I also discussed installing a whole home surge protector inside the electrical panel. The customer wanted me to go ahead and install an April air filter upgrade kit which I did. A new filter will last her a year and will capture smaller particulates of dust and dirt circulating throughout the home. Thank you for choosing Comfort Experts!!


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Contacted homeowner over reccomendations to begin repair process Homeowner will call back tomorrow for me to begin next step process on either repairs or advisor


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Performed evaluation Upon arrival both systems were functioning Deltas upstairs 9&15 Downstairs Replaced both systems filters systems are low on refrigerant Downstairs system has high oil residue when gauging on and off with re occuring bubbling Systems manufacturer 2021 Reccomended leak search estimates for both systems Reccomended estimated refrigerant upon completion of repairs into further evaluation of systems Coil doors on both systems have supporting straps installed and lead into high roof Homeowner will contact original installer and see on repair process Homeowner may call us back to start repair process Systems left on cool at exit


Zak L.

Zak L. Job Checkin

Service eval Dual run capacitor failed L6 error code Replaced capacitor System cooking Motors and refrigerant fine Spoke to her niece. She will call the office to get another filter ordered and schedule us to return and change it Recommend having IAQ200 and anti microbial mist done to the system to eliminate biological growth from the system and airflow


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Found bad run capacitor on condenser replaced dual run cap unit now working properly free on levels good cleaned condenser spoke with customer about protection plan customer would like to think about it and get back to us leaving estimates collected payment by credit card


Jerred G.

Jerred G. Job Checkin

Today I showed up for a 45 after coming out yesterday and dealing with a couple of mechanical issues being the capacitor and the thermostat turns out I was unaware that this model of thermostat requires the W to be put to auxiliary for a heat pump so this is a mistake on me and therefore I have recalled the service fee while I was out here the homeowner asked me to verify his refrigerant levels I found them to be severely low we discussed options for Elite detection and the situation with parts through the manufacturer homeowner was going to have me just put refrigerant in and see how long it lasts but he was trying to get pre-authorization for reimbursement through his Home Warranty company they only offered to reimburse a fraction of the price so he decided that he's going to have the Home Warranty company come out and service the system


Jerred G.

Jerred G. Job Checkin

Today I showed up for an evaluation on a 10-year-old system upon arrival the fan motor was not running and the compressor was trying found a bad capacitor replaced it and realized the system was running in heat mode this is because the thermostat was not sending a call to the reversing valve replaced the thermostat everything is running and Cooling as it should be however I also recommended a deep cleaning of the condensing unit replacing the filter as well as the fan motor due to oil leaking from the motor and the defrost control board is showing signs of burnout also discussed soft start versus hard start homeowner chose to only go with the two repairs today of the capacitor and the thermostat this is the first time out of warranty that either of these items has been purchased moving forward these will be covered under the membership lifetime warranty thank you for choosing comfort experts!


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Performed evaluation Upon arrival system was cooling System performance 17 Delta Home had showing - had windows and doors open for viewing Thermostat is 1-2 Degrees off - it does reach temperature but takes a little more than normal time Reccomended thermostat replacement Reccomended provided C replacement Reccomended membership/star plan 10yr /lifetime System left on cool at exit


adam.brockelman@acgenius.com

adam.brockelman@acgenius.com Job Checkin

Arrived onsite valve under kitchen sink was turned off turned valve on everything working properly.