Upon arrival condensor was off and indoor unit was running Performed evaluation Indoor coil has sever build up of dirt/calcification on under surface and deep into the coil - 0 light showing through coil Reccomended cleaning - not guaranteed to remove all the build up due to calcification - performing the process would also have high caution to coil integrity Both indoor and outdoor motors are overheating Indoor motor has loose rod/bearings - video uploaded Indoor motor cage has severe build up affecting system performance Reccomended both indoor and outdoor motors with cage cleaning Indoor motor OEM with bracket rubber seals - original will tear apart from degradation Primary electrical control unit (high voltage) has pitting and burns Reccomended new control unit Due to severe build up affecting airflow and system performance - unable to accurately determine refrigerant Leaked searched outdoor and top of indoor coil - no leaks found during operation, but cleaning coil could indrodu