Performed 8-12 tune-up on 12-year-old natural gas furnace that had been experiencing intermittent operation. Inspection revealed dirty and torn filter along with rust in heat exchanger. Replaced filter and advised customer to replace monthly while also recommending they begin researching replacement options for the aging system.