Responded to no heat service call for 15+ year old furnace exhibiting intermittent operation. Diagnostic inspection revealed two cracks in heat exchanger, presenting a significant safety hazard. Recommended complete heat exchanger replacement or full furnace replacement as appropriate remedial options given system age and condition.