Responded to no heat call for 9-year-old furnace. Diagnostic inspection revealed significant buildup in secondary heat exchanger and collector box, along with worn motors and ignition components. Performed thorough system evaluation including video inspection of internal components. Based on multiple component failures and system age, recommended either complete system replacement or major component overhaul to restore proper heating functionality.