Responded to no heat call for 2-year-old heat pump system. Diagnostic testing revealed a low pressure lockout condition. Temporarily set system to auxiliary heat mode for immediate heating needs. Follow-up appointment required during warmer weather to properly check refrigerant charge, identify potential leak or restriction, and restore normal heat pump operation.