Performed comprehensive diagnostic on furnace after multiple reported failures. Inspected primary and secondary heat exchangers finding no cracks or damage. Cleaned condensation trap and examined inducer motor. Verified proper gas valve pressure at inlet and outlet, checked fan speed and burner operation. System currently operating normally with no identified issues. Scheduled appointment with comfort advisor to discuss potential equipment replacement options.