Performed annual maintenance on 9-year-old furnace. Conducted comprehensive inspection including heat exchanger examination, combustion analysis, gas pressure verification, and assessment of flame sensor, burners, and blower components. System is operating normally with no immediate concerns identified. Cleaned pressure switch, verified thermostat functionality, and noted moderate air filter condition.