Responded to no-heat service call for LP furnace with non-functioning Nest thermostat. Found tripped rollout switch and heavily rusted burners causing flame irregularities. Reset switch, removed and cleaned burners, verified heat exchanger integrity, and installed new thermostat. Advised customer on future burner replacement due to extensive rust.