Responded to intermittent no heat complaint where system was displaying code 240 (no ignition). Upon arrival, furnace was operational. Performed diagnostic testing including high/low fire verification and gas pressure measurement, all within specifications. Cleaned flame sensor as preventative maintenance. System cycled multiple times without issue during service visit. Customer advised to monitor for any recurrence of intermittent operation.