Responded to service call for non-functioning sensor faucet (Zurn brand). Diagnosed issue with water sensing capability despite battery replacement. Performed comprehensive maintenance including disassembly of faucet, cleaning of filter, verification of wire connections, and inspection of flow past mixing valve. After reassembly, faucet operated correctly with proper sensor function restored.