Responded to no-heat call and diagnosed multiple issues with furnace. Found burners with significant rollback, removed and inspected to discover two cracked burners and a gas leak at deteriorated copper flare connection. Replaced damaged burners and performed repair by cutting and re-flaring gas line to restore safe operation.