-Completed- :Exterior Outlets: At the front door I removed the flip cover and indoor rated outlet and found a shallow box. I removed the box and installed a new deeper cut in box to allow for the GFCI to be installed properly along with a new bubble cover. This was also completed on the lower porch (facing the house) left door and the upper porch open side. The exterior device facing the house on the right side had a plumbing pipe coming down from the ceiling and it contained indoor rated Romex wiring. I removed the pipe and installed a new bell box up high, installed a new 1/2 pvc conduit down the wall to a new bell box. I installed UF wire (outdoor rated) in the new conduit and installed a GFCI with bubble cover down below and made a splice at the higher bell box and installed a weather proof blank. :Interior GFCI: In the basement bedroom just to the right of the heater I installed a GFCI outlet and wired the load side to cover all the standard devices on the circuit and I also i