Karl S.

Karl S.


Job Checkin

Arrived found system cooling set to 80° at 80°. Customer has a couple holes in drywall ceiling covered with plastic. One over the staircase and one in master bathroom. PVC is not insulated. Drain line PVC does not go over master bathroom. It stops right before and goes down. Does not have in-line safety or wet switch. Checked all electrical and amperage. Filter is clean. Checked evaporator coil looks good. Checked drain pan. Checked outdoor unit. Checked capacitor, contactor, and pressures. Capacitor starting to go bad. Ran system for about 45 minutes. Found no water leaking at this time. Customer stated pan has filled up with water, but it evaporated overtime. It is dry at this time.