2011 Goodman Airhandler Checked and tightened all electrical connections Drain was clear and draining at this time Changed customer provided filter Heat strips were functional and within manufacture range Blower cap was within manufacture range Blower Motor and wheel have heavy dust and dirt build up Evaporator coil has heavy dust, dirt and smoke build up 2011 Goodman Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Compressor saver is functional Primary electrical unit was acceptable Defrost board has burn marks Defrost is functional Refrigerant levels were acceptable at this time Fan motor bearings are wearing down and are slightly audible when running Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended level 2 duct cleaning, UV 300, condenser fan motor And replacement of defrost board