Upper level - 2015 Lennox gas furnace and AC System not cooling due to a few reasons. The starting components on the outdoor unit have failed, the condenser coil is impacted with debris, the evaporator coil is rusted and leaking, and the compressor is over amping. This is a Lennox C-33 evaporator coil, these coils were notorious for leaking and actually had a law suit against them. Due to the age, condition, refrigerant type, and cost of all repairs, I recommended considering updating the equipment or at least the AC portion at a minimum. Today the homeowner decided to go with option A the bandaid repair. I replaced the starting components, tested the equipment, and took temperature reading's. At this time the system is working to its best ability and cooling the home. Thank you for choosing T.E. Certified, have a great evening.