Installation: We uncovered the sewer and water penetration in the front of the house. Replaced pex water service line penetration with soft copper and wrapped with 20 mil tape. Resealed both penetrations with hydro cement and roofing tar. In the utility room in basement, we reworked the sewer drop, installed new whole home shut off, PRV, StreamLabs water monitor, Halo Ultimate, and two Rheem 50 gallon electric water heaters. We also sealed water, sewer, and a failed core penetration from the inside. Ensured drain line had proper pitch and everything was up to code. Cleaned and tested everything thoroughly ensuring no leaks. Customer asked if I could take a look at a couple of running toilets upstairs (powder room by kitchen and jack and Jill bathroom). Adjusted the fill valves. This was done as a courtesy and will not warranty.