Mark  H.

Mark H.


Job Checkin

Performed diagnostic on main floor 10yr old unit, upon arrival customer stated unit wasn’t cooling and had water in pan that she had already removed, checked tstat, was off due to customer had power to unit off, turned on power, cycled tstat to ac mode, inspected furnace , found secondary drain pan and inside of furnace heavily rusted, recommend TE Flood protection wet switch, customer approved, install wet switch and tested, poured water in primary pan , all drained properly,checked blower wheel, blower capacitor, inspected evap coil, explained to customer it has rust as well and can cause leaks, checked outdoor unit, condenser coil impacted, recommend chemical cleaning, checked contactor, capacitor reading below specs, recommend replacing capacitor, explain weak capacitor can cause failure to compressor and condenser fan motor, checked amp draw, explain compressor is over amping and can fail at any time, recommended hard start kit to help lower amps, explained not a guarantee fix and