Whole House Lightning Check-up in Standard Size Home. Includes a visual inspection of all major electrical fixtures, devices, and detailed panel inspection. Includes voltage and amperage check of circuits at electrical panel. Does not include plug-in electronics not affixed to the house. Does not include megohmmeter testing. FINDINGS: must do lightning inspection to fully check house. -for this inspection we checked and tested the main components of the electrical system such as the meter, disconnect and panel, testing voltage on all breakers and lugs. During this process we found there to be no whole house surge protector which is required by the National Electrical Code. Also there is no ground wire going to the water line from the main breaker outside of the home, which is something that is required by the National Electrical Code. The water line must be bonded to the first point of disconnect. During that process we will bond the hot and cold water lines at the water heater as requ