9800 Old Dogwood Rd.
Roswell, GA 30075
(770) 667-6937

Our Top Cities


Job Locations
for riverdale, ga


Map of Riverdale GA
Mason C.

Mason C.


Job Checkin

Came out today due to system not cooling. Upon a visual inspection found no water in the drain pan that was triggering the aqua guard. I also found that the indoor system was running, but it was not cooling. It was blowing out warmer. Upon inspection of the outdoor system had no power at the disconnect. Upon inspection of the outdoor system found that the 10 gauge wire going into the system was not installed properly, and it was just hanging the vibration of the system from running, had sliced through the metal wire because there was no Romax connector connected to secure the wire. Also upon inspection found that the outdoor capacitor is bad on the fan side, the contactor is very burnt impeded, the indoor system has no TE standard flood protection, there is no UV protection on the system, upon inspection of the inside system found that the evaporator coil is very dirty. Upon presenting all options to homeowner, he only chose to do a Band-Aid repair, which was to get the system back up