Took video of my diagnosis of the ejection pump for the basement. The pump on an extension cord, running from another g fci from the basement kitchen was able to pump and run multiple times but if ran off of the gfci next to the ejection pump within the utility closet, the g f c I would automatically trip the second the pump attempted to kick on again.I have taken video recording of this happening and have had dispatch schedule an electrician to come out tomorrow to see what's going on. While at the residence, I informed the customer that their pressure regulating valve was 10 years old. And of a lower quality and also under sized. I recommended replacing the pressure regulating valve. Customer agreed to my recommended quote. I turned the water off to the house from the basement and drained all the water out of the line. I then replaced the pressure regulating valve with a new twenty five a u b. Afterwards, I slowly primed all of the air out of the lines.And tested for leaks no leaks.