Main Level - Not Cooling (24 year old Trane System) System not cooling due to multiple issues, all issues lead back to the equipment’s age, 24 years old. The compressor has failed, the run winding is reading very low .58, and the start winding is reading 0. Due to the refrigerant type ( R-22 ) the parts for this equipment are no longer available due to restrictions from the government mandated phase out of the refrigerant. The heat exchanger has multiple cracks in it, making this gas furnace, unsafe for heating. The evaporator coil is very rusted and leaking slowly. The blower wheel in the furnace is impacted with debris, and the blower motor is leaking oil at the main seal. Due to the age, condition, and not all repairs available, Ginger requested we send out an install supervisor to go over updating the equipment. Thank you for choosing T.E. Certified, have a great weekend!