1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Job Locations
for carrollton, tx


Map of Carrollton TX
leo.huerta@acgenius.com

leo.huerta@acgenius.com


Job Checkin

Cooling tune up, Condenser is undersized, not cooling entire home we’ll 3 ton when it should be at least 4 tons Customer states that daughters rooms are not cooling efficiently Evaporator coil is oversized, losing efficiency as well there Washed the condenser, poured a gallon of water down condensate line and it took i, no issues Disconnect wasn’t found easily, it took a while to find, it was inside breaker panel, needs its own disconnect, safety issue and legality problem probably To fix issue with cooling, Condenser and evaporator coil must be replaced and sized appropriately Home is 2400 square feet, 600 sq feet per ton, 4 Ton is the minimum size Had a 22 degree delta, no issues with refrigerant levels Thank you for choosing Comfort Experts, have a great day