11/20/25 Tech is pausing job due to weather 2017 Carrier Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining at this time Heatstrips were functional and within manufacture range Blower motor and wheel were acceptable Blower wires, cage and cabin have biological growth build up Evaporator coil has slight dust and dirt build up Evaporator coil header plate have biological growth build up 2017 Carrier Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Compressor saver had failed, replaced under warranty Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended UV system for the biological growth build u