Homeowner is a flipper, currently resides in home though. Indoor is goodman 2009 and outdoor is carrier 2022. Expired manufacturers warranty. Evaporator coil is heavily blocked and leaking detectable refrigerant. Coil has a history of freezing. Blower wheel has extreme buildup and heavy biological growth. Filter system is poor. Condenser unit is not level. Refrigerant levels are low. Inrush amperage on compressor exceeds manufacturers tolerance. Contactor is buzzing. Homeowner wants condenser unit moved around the corner. As I uncovered all the issues, decided to talk to a CA 4/5/25 @10am. Homeowner needed information to give to his insurance company of the year of both systems so I made an estimate with that information and emailed it. I also encouraged him to not deliver the information to insurance company if he infact replaces the system. System is functional but heavily diminishing in performance.