97 Amana gas furnace Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were heavily compacted with dust and dirt Blower auxiliary motor starter is weak Evaporator coil has slight dust and dirt build up Furnace door switch is bypassed 97 Amana straight electric Checked and tightened all electrical connections Dual run capacitor is weak Primary electrical unit has heavy pitting and carbon build up Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Both Blower and Dual run cap replacements, Primary electrical unit, furnace door switch, level 2 duct cleaning Setup up plumbing and electrical visits for multiple shutoffs leaking, slow Drains, loose toilets, water heater issues, and multiple plugs not functioning properly