Homeowner has a water service that is leaking somewhere under the foundation of the house. The leak is rather slow however it is not presenting any obvious symptoms. Confirmed existence of leak by isolation the main line. Shut off up quarter turn valve inside house and the meter still showed movement. Trenched from meter to flower bed. Bored under flower bed and sidewalk to house. Installed 1” HDPE piping from meter to house, under sidewalk. Pipe is set approximately 18” deep into the ground. At the meter I installed a new meter nipple, a new 1” quarter turn PEX ball valve, and a new 1” dual check assembly. Drilled through foundation of house in the corner of the garage. Sleeved 3/4” Type L soft copper through foundation. Copper is wrapped with burial tape. Connected onto 3/4” PEX outside, and then upsized to 1” to connect to HDPE. Inside the garage, I ran approximately 20 feet of 3/4” PEX along the wall and ceiling, supported via bell hanger approximately every 5 feet. Drilled throug