Upstairs System - 1995 Ruud system System not heating due to age. System has multiple issues and all original components. The heat exchanger is cracked, the inducer assembly has multiple cracks, the blower wheel is impacted with debris and the blower motor is leaking oil at the main seal. The igniter is bad and the flame rectifier is very weak. The system has no wet switch or flood protection in the drain line or secondary and the drain line has been cut multiple times to clear clogs. Abundant rust and water damage discoloration show that at some time the system was flooded or had water running through it, most likely from a clogged drain line or coil freezing. Due to the age, condition, and lack of parts available for a 30+ year old system, I recommended updating the equipment. We scheduled for an install supervisor to come out this afternoon! Thank you for choosing T.E. Certified, have a great day!