Tech arrived to no heat call for downstairs system. System is approximately 10 years old. Inspected system. Saw thermostat had active call for heat coming from thermostat. Furnace was not doing anything. Code on furnace did not indicate any failure other than normal operation. Checked all safety switches, no water in pan and no secondary tripped. Reset power and watched. Furnace came on immediately and fired up as intended. Found furnace inducer to be noisy and overamping. Also found thermostat to be failed. Brought recommendations to customer. Customer agreed to replace inducer motor today and will change out thermostat to something else on own time, as thermostat is somewhat operational. Replaced inducer motor, and verified operations. System is operational and heating at techs departure. Thank you for letting TE CERTIFIED service your home.