Ricardo V.

Ricardo V.


Job Checkin

Main level system not working due to a bad transformer and burnt blower motor wire. Also, heat exchanger is very rusted and possible leaking Co. Blower wheel super dirty and evaporator coil with biological growth. Furnace is from 1997, condenser 2013 and evaporator coil 2012. No drain pan under the furnaces, one condensate pump connecting both systems and no flood protection devices at all. Due tot he age and conditions of the system, the best option would be to upgrade the system, and bring safety, comfort and efficiency back to the house. Basement system is 26 years old and runs with r22 Freon. Customer wants a quote for the main level and possible for the basement , as well. Set a lead to quote upgrading for the min level and possible the basement system for today. We should credit 98,00 back if customer decides to upgrade the system.