Upon arrival, I was pointed to the basement where there was a freeze break. This freeze break happened to the hose bib line that goes to the hose bib that is attached to the deck. This freeze break was after the isolation valve. I was also pointed to the old gas line that was for the grill on the deck. This gas line was broken off and not capped outside. After providing options and upon approval, we fixed the freeze break installing a tee which allowed a drain valve to be installed. We also removed a section of gas pipe in order for us to cap off the gas line right after the isolation valve and the gas line going outside. We silicone the gas line outside in order to prevent dirt, moisture or debris to get into that line. Tested everything for leaks and proper function no further issues at this time.