Main level not heating - 24 yr old gas furnace / 16 yr old AC/Coil The heating system is inoperable due to age-related deterioration and recent water damage. A water leak occurred last night, resulting in significant exposure to internal components. As a result, the gas valve has completely failed in the closed position, and the control board is operating intermittently. A full inspection of the furnace and evaporator coil was performed to assess additional damage. The heat exchanger was found to have small cracks. The evaporator coil is heavily coated with biological growth and debris, the evaporator drain pan is cracked, and the coil itself shows extensive rust and possible refrigerant leakage. Additionally, the blower wheel is heavily impacted with debris, and the blower motor is seeping oil at the main seal. Considering the system’s age, overall condition, extent of damage, and parts availability, replacement of the equipment is recommended. Thank you for choosing T.E. Certifie