Electrical Panel Replacement The existing electrical panel is overloaded and improperly configured. It contains multiple tandem breakers, even though the panel is not rated or listed for tandem breaker use. This condition exceeds the panel’s designed capacity and violates manufacturer listing requirements, creating a serious safety hazard. Additionally, there is visible overheating and discoloration on the neutral bus bar and Phase A bus bar. This discoloration is a clear indicator of excessive heat caused by poor connections or sustained overcurrent conditions. Overheating at the bus bars can lead to: * Increased resistance and further heat buildup * Breaker failure or arcing * Damage to connected branch circuits * Elevated risk of electrical fire Because the bus bars are integral to the panel assembly and cannot be safely repaired, full panel replacement is required to restore safe and code-compliant operation. New Panel Installation The existing panel will be removed and repl