Customer had vibrations coming from not only the upstairs hallway toilet valve.But from the pressure regulating valve. Pressure on the house was at eighty p s I. As well, the same toilet was very slow to fill due to a clogged fill valve. Customer agreed to have all these items addressed. We replaced the emergency, shut off and PR. V in the basement, after turning the water off and draining all of the lines. While letting that dry, I then replaced the shutoff valve for that upstairs.Hallway toilet and replaced supply line fill valve and flapper of the exact same toilet. Allowed two hour cure time as some of the fittings were on the high pressure side. Afterward, we slowly turn the water back on to the home at the meter and pressure tested the water service line. That was fine. Afterwards I went to our newly installed ball valve and slowly turned it partially on and primed all of the air out of the waterlines throughout the home. Checking for leaks on the way and making sure that no face