2710 Northridge Dr. Suite #F
Grand Rapids, MI 49544
1-800-968-2871

Our Top Cities


Local Reviews
for milford charter township, mi

Rated 4.8 out of 5 stars based on 4 customer reviews

Excellent Service!

Friendly, knowledgeable staff! Quick service and always on time. Excellent customer service.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Thank you

Very good service.

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great Service!

Jared was friendly and quick while inspecting our fire extinguishers!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well pleased

Very thorough. Waiting for invoice with cost attached to rate pricing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for milford charter township, mi

George S.

George S. Job Checkin


Terrence  J.

Terrence J. Job Checkin

1/24/24 Tentative schedule for 1/25/24 DH 1/18/24MV Emailed Tom and Todd regarding inspection date 1/23, waiting on confirmation Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)


Terrence  J.

Terrence J. Job Checkin

2/2/23MV Emailed customer regarding inspection date 2/3, waiting on confirmation this customer is on hold. he has an past due invoice that is 118 days past due. lr Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: Corroded sprinkler heads shall be replaced with new. 1- kitchen by MOD office 155 QR 3/4 ELO 1- janitor closet across from MOD office 1/2” 286 SR chrm pend 1- dish wash area 155 QR 3/4” ELO Deficiency: Missing outer esc located kitchen 2- Viking white Deficiency: Fire sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Spare head box will need an additional sprinkler head. 1- 155° chrome pendant extended coverage three-quarter inch sprinkler head. Deficiency: There are two dry pendant heads that are not in a cooler. They are just hanging from the ceiling and must be removed and plugged. 2- 1” Plugs Deficiency: Sprinkler system is due for five year internal obstruction investigation of piping. 2- 4” Victaulic Coupli


Mark S.

Mark S. Job Checkin


Sean W.

Sean W. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


Terrence  J.

Terrence J. Job Checkin

Sprinkler Inspection Annual Sprinkler System Inspection (1 wet system) 5-Year Internal Due: 2024 FDC Hydro Due: 2024


Mark S.

Mark S. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


Robert G.

Robert G. Job Checkin


George S.

George S. Job Checkin


George S.

George S. Job Checkin