2330 Indian Springs Rd
Dudley, NC 28333
(919) 734-9611

Our Top Cities


Job Locations
for rocky mount, nc


Map of Rocky Mount NC
Derek J.

Derek J.


Job Checkin

Upon arrival tech was informed system was not running. Tech inspected equipment and found AH break tripped under house. Tech reset breaker and system came back on. Other findings consist of Condensate drain for system is going up hill about out 2-3 inches, there is no receptacle for condensate pump. Informed home owner they will need to get electrician to install one and let call us when completed so pump can be installed. There was a hole in one of the return flex lines, will need 12” splice collar and about 10ft of 12” flex to make repair. Disconnect for condenser is in pretty bad shape. Estimates were sent to homeowner for repairs and told to call us when they were ready. System was left off at breaking inside house due to not having proper fall on drain. Tech also informed customer that there could be other issues but would need to make necessary repairs first in order to fuller check rest of system.