Spencer C.

Spencer C.


Job Checkin

Tech found inducer motor locked up. Tech spun the motor and could tell the bearings have gone bad. Tech tested the rest of the system and found compressor pulling 83 start amps rated at 73. This indicates the compressor will soon be locking up and will not be able to start. Tech found evaporator coil not leaking, but showing signs of a potential leak in the near future. Tech verified the capacitor was good and not causing the compressor to pull LRA. Tech recommends replacing unit due to age and cost of repair. If customer does not want to replace unit, inducer motor will need to be replaced and hard start installed to extend compressor life. Field supervisor present with tech.