1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for westworth village, tx

Rated 5.0 out of 5 stars based on 10 customer reviews

Excellent service

Good service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Jerred was phenomenal. Very grateful he was our tech. Extremely thorough and helpful. Will always request him when we call!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Estimate

Very knowledgeable and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Thank you for prompt friendly service! Another 110 degree day and he completed everything. Knowledgeable and friendly. Asset to Hobson Air conditioning!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Super service! Hobson Air is fortunate to have Ryan on their team

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Ryan listened to my AC concerns and knew what needed to be done. Ryan is a true professional. Ryan and Brock worked efficiently and my AC is working perfectly. Thank you for all you do!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous, professional, and knowledgeable

Our technician, Eddie Navarro, was courteous and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly people. Professional Service.

Professional service with thorough knowledge of the work required.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional Service!

Marshall G. completed a thorough maintenance check on our AC and Heating system and provided information on services available from Comfort Experts, Inc. Professional and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for westworth village, tx

wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

Found clogged drain clear drain unit now draining properly paid in full by credit card


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Spoke with customer about changing TXV to piston to get better cooling capacity out of their unit sending estimate to customer also spoke with customer about service agreement


nathaniel.burke@acgenius.com

nathaniel.burke@acgenius.com Job Checkin

At arrival circuit breaker was defective with only 1 leg supplying 105volts. Replaced circuit breaker. Made a STRONG recommendation to upgrade service. Stating multiple concerns with age and installation integrity.


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Performed evaluation Upon arrival system was off Restored power and indoor unit turned on Outdoor unit was not operational Main electrical components on condensor are in tolerance Inconsistent high voltage to disconnect 105 right terminal 10 Left terminal Inspected main breaker box and found multiple breakers are tripped Once resetting burning smell came from breaker box (lower breaker bottom box) Due to multiple levels of failure electrical inspection is reccomended System left off at exit Schedule electrical technician for tomorrow 05/14/25


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

We will install 1/4 turn stops at 3 toilets


garrett.young@acgenius.com

garrett.young@acgenius.com Job Checkin

Customer had questions about adding water safety, answered their questions and installed it. Tested and worked like it's supposed to.


garrett.young@acgenius.com

garrett.young@acgenius.com Job Checkin

3/5/25 Customer was called into work and not home at the time


garrett.young@acgenius.com

garrett.young@acgenius.com Job Checkin

For this evaluation the customers furnace was throwing a high limit switch code and igniter code. I reset the system and the igniter would randomly ignite when the gas valve was opening signifying that igniter is failing and not getting hot enough. Additionally the high limit switch is faulty, the filter is clean and both zones were opened when the furnace was running and the system was not going over 125⁰F. The limit switch will have to be ordered and I will return once it arrives to install it. I recommend installing a float switch to the primary drain line as there is no water safety on the system to prevent flooding in case of a clog within the drain line.


dakota.bise@acgenius.com

dakota.bise@acgenius.com Job Checkin

Arrived at customers house for super tuneup Outdoor capacitor severally out of tolerance 70 is pulling 2 Showed customer and Recommended replacement Recommended membership conversion Recommended pan strip for drain line All declined as of now


katie c.

katie c. Job Checkin


Lisa M.

Lisa M. Job Checkin


Tyler L.

Tyler L. Job Checkin

She's been having trouble with some GFCI ch breakers so I explained exactly what is happening and why, they are going to order some breakers of their own to replace the problematic ones


Alex  D.

Alex D. Job Checkin

Alex D - recovered refrigerant from unit cut off and redid existing flares to outdoor unit pressure tested and checked for leaks with soap bubbles pulled vacuum and recharged unit with r-32 3.3lbs


Cody B.

Cody B. Job Checkin

THIS IS A RECALL ON THE INSTALL TEAM Techs Cody and Anthony arrived to customer's home and met the homeowner. When we arrived the mini split was not cooling and was giving a low refrigerating error code. We conducted a leak search and found the flare fitting connections on the outdoor unit were covered in oil residue and we got a confirmation hit with out leak detector. We called Joe S. to inform him of the issue because this is a new install, he said he would send out an install team to remedy the leak and refill the system with R32 refrigerant. We informed the customer that an install team would make it's way out and repair the system. System was down when we left.


Cody B.

Cody B. Job Checkin

Tech Cody and Anthony arrived to customer's home and met the homeowner. When we arrived the garage mini split was not cooling. The indoor unit would come on and the fan would turn on but the outdoor unit was not running. We turned off high voltage for 5 minutes and turned it back on to let the system reboot. After the reboot the system turned on and began to cool, we turned the system on and off two times with the remote and the system operated normally the whole time. We shared our findings with the homeowner and explained how he could reboot the system if he needed to. System was cooling when we left.