1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for brock, tx

Rated 4.5 out of 5 stars based on 4 customer reviews

Great Service

Very nice man, friendly and seems very knowledgeable. A great first time service offer. Would definitely recommend them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician. Part to be ordered.

Was very satisfied with Dennis and his work and knowledge of HVAC units. Send him anytime he is available. Office personnel were polite and helpful.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pleasant/courteous

Appeared to be knowledgeable and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

polite, informative, knowledgeable

Dalton is a polite and courteous individual. He also endeavors to correct/repair any problems with the HVAC unit. Also important is that he listens to the customer regarding problems with the unit and lets the customer know that he values their input. Great Technician


Response from Comfort Experts Inc.:

Thank you for being our customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for brock, tx

abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Installed 3 customer provided lav faucets one kitchen faucet and toilet fill valve tested for leaks no leaks job complete


Mark W.

Mark W. Job Checkin

No problem when I got here


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

This is not a call back there are no leaks tested water heater there is no power now going to the water heater seems to be issue with power coming from breaker box picked up check for comfort experts customer is not home until after 4 per mark can go bk to check electrical at 4


Kellen M.

Kellen M. Job Checkin

2015 furnace. 2025 evaporator coil. 2020 condenser unit. 1" filter replaced. Drain clear. Blower clean. Evaporator coil clean. Condenser unit washed. Refrigerant charge acceptable. DeltaT acceptable. Dryer vent is venting into attic and there is a lot of lint all about. No attic tent. Homeowner is aware of all systems and it's functions. Homeowner told me his wife passed in Oct 2024 and he has minimal finances to get the products I spoke about.


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

5/31/25 When we arrived the homeowner said he shutoff the system because water was leaking through his ceiling. Nathaniel and Aaron went into the attic and flushed a gallon of water through the primary and secondary drain, checked drain pan for cracked pan also checked duct pressures and temp splits, checked refrigerant pressures including superheat and subcool. The secondary drain did not have water in it and was letting air back in causing the primary drain to not drain backing water up into blower area. Filled both traps cycled on system for an hour and rechecked, unit is working good at this time. Previous spots of water are dry in the system, I do not see any visable damage from the water. We will come back Monday and double check install again. 6/2 Aaron checked back and went into the attic and checked the sheetrock it was all dry so I moved insulation back around. Hooked up gauges checked refrigerant pressures including superheat and subcool and added 16 Oz of Refrigerant to


Jose  G.

Jose G. Job Checkin

Install 42k hz heat pump keep current filtration includes code kit, new supply plenum and duct seal


Mark W.

Mark W. Job Checkin

5/29/25 Pausing job will finish water tomorrow morning Daniel and Mark W Job is complete installed all new water lines from well to fixtures in home Thoroughly explained to home owner per me and mark some sort of building or shield needs to be built around well housing pressure tank and filter to protect from freezing temps Job is complete JOB IS FINANCED THROUGH GOODLEAP Customer is gonna do customer provided faucets when she calls bk in a few wks she wants Daniel and Mark


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Sold level 3 electric h/p horizontal 42k with code kit, rebuild supply plenum and seal.


Kellen M.

Kellen M. Job Checkin

Homeowner states as I arrived that they are moving. Home is being boxed up. Inspection complete. Filters replaced. Drain lines clear. Indoor units clean. Main unit UV bulb is outside of manufacturer specifications of kill ratio of 24 months. Blower wheels clean. Condenser coils cleaned. Refrigerant charge acceptable. Amps and volts acceptable. Offered duct cleaning service. Both systems cooling well. Left pool house system off and main house to the desired homeowner temp upon departure.


Mark D.

Mark D. Job Checkin

Previous technician had removed the silicon hose on the furnace pressure switch and had caused the burners to not come on. Reattached the hose and performed function check. System running normally upon departure.


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Upon arrival tech removed old evaporator coil tech installed new evaporator coil tech did a pressure test as well as pull a vacuum down to 500 microns tech let the vacuum hold forn15 minutes once tech was 100% positive that there was no leaked tech charged system to its proper refrigerant readings tech then cleaned up work space and talked to homeowner


Mark D.

Mark D. Job Checkin

Arrived to no cool. Found that the system had shut down on a high pressure sensor. Performed a hard reset and system started up. All pressures and temperatures were in normal range. Let the system run for about 45 minutes to try to see if the system would fail again. Could not diagnose a reason for the failure. System running and cooling the home upon departure.


Mark D.

Mark D. Job Checkin

.Need to order an evaporator coil for Goodman


Cody B.

Cody B. Job Checkin

Tech Cody arrived to customer's home and met the homeowner. Main house system is a 6yo amana heat pump, pool house is a 11yo comfort maker heat pump. Main House: INDOOR: System had a temperature split of 19 degrees, I replaced the filter, the coil was clean, UV light was installed and operating normally, the blower was clean, the blower motor was in good condition, the heat strips were functioning within range. OUTDOOR: I washed and waxed the unit before taking any readings, the compressor and fan motor were operating within manufacturer range, the auxiliary motor starter was within tolerance, the unit had a compressor saver installed. The refrigerant charge was within acceptable levels at this time. Pool House: INDOOR: System had a temperature split of 18 degrees, the homeowner will get a replacement filter for the unit today, the coil was clean, the blower was clean, the blower motor was in good condition. OUTDOOR: I washed the unit before taking any readings. The compressor and


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

We will replace pressure switch at well. No warranty on tank or existing plumbing After replacing switch and Galvanized nipple I was unable to pressurize system. I can feel the pump running but can get no water. We will bill this customer


BESbswy