1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for rowlett, tx

Rated 5.0 out of 5 stars based on 10 customer reviews

Great Service!

Blake was to be very thorough and explained everything that he found clearly. I didn’t do all he recommended because of the cost but that which I felt was the most important at this time the most

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Was informed of his pending arrival prior to arriving. Very professional and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thorough, great service!

Blake took his time and did a great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Devyn was very professional and went over everything he did and made a couple of suggestions but was not pushy! Very professional and mannerly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

He did a great job,

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service.

Dennis is awesome. Very thorough. Explains all in great detail. Overall experience total greatness. Thank you Dennis.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Technician was quick and efficient.


Response from Comfort Experts Inc.:

Thank you Brad!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional service!


Response from Comfort Experts Inc.:

Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Simon

very Friendly dud an awesome job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Fantastic job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rowlett, tx

garrett.young@acgenius.com

garrett.young@acgenius.com Job Checkin

For the schooling tonight I expected the furnace and condenser, all equipment was measuring with a manufacturer's specs and running well. Due to the condenser being 5 years old I recommended a compressor saver to lower the amp draw at in Rush and the customer decided to go with that as well as a pan strip as her drain line was starting to be slow with training. At your installing the compressor saver the inrush went down by approximately 30%.


Daniel S.

Daniel S. Job Checkin

No show


Alec G.

Alec G. Job Checkin

During inspection discovered that drain line was clogged and was tripping the drain switch Got drain line cleared and found the clog was in the bathroom p trap Left customers house with system operating properly


Blake  B.

Blake B. Job Checkin

Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The surge protector was functioning. The filter was dirty and replaced. The drain was clear and bleach was poured. The UV system was functioning. The Delta and refrigerant was within range. The customer was informed of recommendations today. We will wait until the next trip to upgrade the UV system when the current bulb is expired. The system was functioning upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a membership tune-up. Upon inspection, the blower capacitor was out of tolerance. The there was an outdated box filter installed. The Delta and refrigerant was out of range. The drain was clear and bleach was poured. The heating system reached complete ignition. The UV system was not functioning. The customer was informed of recommendations today. She decided to move forward with replacing the capacitor and adjusting the refrigerant. These tasks were performed and tested. The system was functioning upon departure. She will consider other recommendations and call back in at a later date.


katie c.

katie c. Job Checkin


Blake  B.

Blake B. Job Checkin

Tech arrived at a warranty tuneup. Upon inspection the capacitor was within specs. The outside system was functioning. The filter was dirty and replaced. The ductwork and blower area was dirty. The system had growth throughout. The Delta was within range. The condenser coils were hosed off to assist with air flow across the coils. The customer was informed of recommendations today. She will speak to her husband about ductwork and the IAQ 200 System and Air Cleaner. The system was functioning upon departure.


katie c.

katie c. Job Checkin


Lisa M.

Lisa M. Job Checkin

Mike R. completed a duct cleaning quote.


Alec G.

Alec G. Job Checkin

During inspection verified that system was working properly Spoke to customers about recommendations for the system to help prevent buildup and extend the life of the system and customers wanted to have some time to talk it over before committing to anything and said they would call us if they decided to move forward with any recommendations


Mike R.

Mike R. Job Checkin

System could benifit from level duct cleaning and auv system. All this is in my estimates. She needs to talk to husband before any decisions can be made.


Blake  B.

Blake B. Job Checkin

Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The Delta and refrigerant was within range. The filter was dirty and replaced. The drain was clear and bleach was poured. The customer was informed of recommendations today. He decided to move forward with upgrading the box filter to an AprilAire filter. The filter kit was installed and the new filter was installed. The customer was given reorder information. The system was functioning upon departure.


Tyler L.

Tyler L. Job Checkin

Tyler L completed electrical tune-up opened up the panel tightened connections had a surge protector as well everything was good inside of the panel there was an open low voltage box outside as well we put a plug cover on a plug in the living room we replaced a plug in the living room as well and replaced a outlet in a bathroom with a GFCI


Blake  B.

Blake B. Job Checkin

Tech arrived at a 45. Upon inspection, the system was not cooling. The outside disconnect was checked and was in the Office position. The breaker was repositioned and the system regained functionality. The system was cooling upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a membership tune-up. Upon inspection, the duel run capacitor was within specs. The contactor had minor scorching. The filter was dirty and replaced. The drain was clear and bleach was poured. The UVC system was switch to run continuously. The basic UV bulb was out. The heating system reached complete ignition. The inducer motor was pulling close to max amps. The customer was informed of recommendations today. He decided to move forward with replacing the basic UV bulb. This item was replaced and functioning. The system was functioning upon departure.