Blake was to be very thorough and explained everything that he found clearly. I didn’t do all he recommended because of the cost but that which I felt was the most important at this time the most
Was informed of his pending arrival prior to arriving. Very professional and thorough.
Devyn was very professional and went over everything he did and made a couple of suggestions but was not pushy! Very professional and mannerly!
Dennis is awesome. Very thorough. Explains all in great detail. Overall experience total greatness. Thank you Dennis.
Technician was quick and efficient.
Response from Comfort Experts Inc.:
Thank you Brad!
On this job I inspected the gas furnace and found everything in tolerance. I did find a bad uv bulb. Today they have decided to upgrade to the iaq200. Heat differential is 30 system has a new filter and is ready for heating season.
Arrived for HTU All components were working and intolerance Recommmend UV Bulb Customer wants to buy his own 24v uV bulb
For this evaluation I showed up to the customer's house and the downstairs unit was not running. Inside there was a call for cool, but only hot air was being blown. There was no sound coming from the condenser to indicate the capacitor was out, which I did test and it was still within tolerance. However there was not high voltage at the contactor and the breaker was tripped at the disconnect. I unplugged the compressor and turned the system back on and the fan ran and did not trip the breaker, indicating the compressor is grounded. Customer stated after the storms in May, that's when she started to notice that her AC was not running as efficiently. My phone the customer that this is because the compressor is basically fried and that is the heart of the system and there's no refrigerant being pumped to cool the house.
For the schooling tonight I expected the furnace and condenser, all equipment was measuring with a manufacturer's specs and running well. Due to the condenser being 5 years old I recommended a compressor saver to lower the amp draw at in Rush and the customer decided to go with that as well as a pan strip as her drain line was starting to be slow with training. At your installing the compressor saver the inrush went down by approximately 30%.
During inspection discovered that drain line was clogged and was tripping the drain switch Got drain line cleared and found the clog was in the bathroom p trap Left customers house with system operating properly
Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The surge protector was functioning. The filter was dirty and replaced. The drain was clear and bleach was poured. The UV system was functioning. The Delta and refrigerant was within range. The customer was informed of recommendations today. We will wait until the next trip to upgrade the UV system when the current bulb is expired. The system was functioning upon departure.
Tech arrived at a membership tune-up. Upon inspection, the blower capacitor was out of tolerance. The there was an outdated box filter installed. The Delta and refrigerant was out of range. The drain was clear and bleach was poured. The heating system reached complete ignition. The UV system was not functioning. The customer was informed of recommendations today. She decided to move forward with replacing the capacitor and adjusting the refrigerant. These tasks were performed and tested. The system was functioning upon departure. She will consider other recommendations and call back in at a later date.
Tech arrived at a warranty tuneup. Upon inspection the capacitor was within specs. The outside system was functioning. The filter was dirty and replaced. The ductwork and blower area was dirty. The system had growth throughout. The Delta was within range. The condenser coils were hosed off to assist with air flow across the coils. The customer was informed of recommendations today. She will speak to her husband about ductwork and the IAQ 200 System and Air Cleaner. The system was functioning upon departure.
During inspection verified that system was working properly Spoke to customers about recommendations for the system to help prevent buildup and extend the life of the system and customers wanted to have some time to talk it over before committing to anything and said they would call us if they decided to move forward with any recommendations
System could benifit from level duct cleaning and auv system. All this is in my estimates. She needs to talk to husband before any decisions can be made.
Tech arrived at a membership tune-up. Upon inspection, the capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The Delta and refrigerant was within range. The filter was dirty and replaced. The drain was clear and bleach was poured. The customer was informed of recommendations today. He decided to move forward with upgrading the box filter to an AprilAire filter. The filter kit was installed and the new filter was installed. The customer was given reorder information. The system was functioning upon departure.