102 customer's house for police said by AC tech for plugs not working in house in bathrooms and got here and bathroom plugs were not working but Breaker was tripped in garage talk to customer about it and got information on whenever she would plug in a hair dryer or something with a little bit higher amperage pool it would trip immediately and after pulling the cover off found that they had the neutral on the breaker not even tighten down at all and was just loose dangling around and was causing it to arc and trip the breaker So just tighten down the neutral wire and everything is working panel was a federal Pacific that but that is a lot for her right now but panel look really neat for what it was other than the loose connection there was no other issues other than not having a main breaker on the panel or disconnect on the outside talk to her about doing a membership but customer was not interested at all in it