Mark D.

Mark D.


Job Checkin

Arrived to no cool on Pioneer mini split heat pump installed in 2022. Compressor and blower motor turn on but variable speed condenser fan motor will not run and system goes out on high pressure. Power is being delivered to the motor via the control board but condenser fan motor will not run. The motor has failed and needs to be replaced. Customer declined repairs at this time.