Job Checkin

Upon arrival customer stated outdoor system sounded louder than normal. Checked refrigerant levels and found no issues, checked all connections and run capacitor everything was within manufacture range. The RLA for the compressor was 23.7 running amps at this time were 17.9, slightly high but still withing manufacture range. Indoor is 2023 model and outdoor is 2024. Unable to find out with homeowner if the outdoor was replaced before moving in. If so could be possible that the system was not fully evacuated and compressor is running loud due to that. Recommended customer continue to keep an eye on the system and to call for any other issues. Setup comfort advisor for generator and electrician for plug thats not working in living room confirmed by the office