2024 Amana Airhandler Checked and tightened all electrical connections Changed customer provided filter Filter is slightly too small for filter box Drain was clear and draining at this time UV lamp was out on arrival Heat strips were functional and within manufacture range Blower Motor and wheel were acceptable Evaporator coil was acceptable 2024 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable Defrost is functional Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Roof does not have a Heatpump gutter so when it rains and freezes ice will build up and keep fan from working properly. Recommended UV system upgrade or replacement of the UV lamp along with Heatpump gutter