Upon arrival customer stated that the system would not do anything during evaluation found that the thermostat was set to cool with the fan on while the air handler did nothing along with the heat pump found that the transformer had failed receiving 240 volts but was not stepping it down in 24 replace transformer under warranty reset system as system was running notice the fuse would pop isolated the short to the heat pump found that the solenoid wires to the compressor had melted to the compressor along with the plugs for the for the windings and the solenoid compressor got extremely hot melted wires causing it to pop the fuse unable to test compressor or get it to run condenser is DOA need to order new Amana two-stage condenser