2025 Ducane Airhandler Checked and tightened all electrical connections Changed customer provided filter Drain was clear and draining at this time Heat strips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable Biological growth is beginning to grow on condensate pan and inside supply plenum 2025 Ducane Heatpump Checked and tightened all electrical connections Dual run cap was within manufacture range Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Waxed top of the unit Recommended micro air soft start kit and UV system for biological growth in Airhandler and plenum Customer is interested in Micro Air Soft start and UV 300. ALSO IS INTERESTED IN ROLLING THOSE