1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Job Locations
for mansfield, tx


Map of Mansfield TX
Zak L.

Zak L.


Job Checkin

Super tune ups upstairs and downstairs system Downstairs furnace is new. Condenser and coil are from 2005 and are low on refrigerant and actively freezing up No water safety present and the secondary drain pan is rusted through Upstairs system has a 2005 furnace but a new condenser and coil Furnace ignitor and flame sensor are nearing failure Blower is extremely dusty and losing efficiency on the new AC system Both systems have biological growth present in the supply plenums Homeowner is aware of all issues and does not want them addressed at this time