1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for ponder, tx

Rated 5.0 out of 5 stars based on 4 customer reviews

Excellent Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Colby F. is a very polite young man who takes a lot of pride in doing his work and doing is very well. He was very diligent in working in a timely manner and explained everything to my understanding. I will request him the next time a technician is needed to work on my unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service for 20+ years, priced just right!

Every tech we have had has been extremely courteous, polite and respectful. Have been satisfied every time they have been to the house.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ponder, tx

katie c.

katie c. Job Checkin


michael.martinez@acgenius.com

michael.martinez@acgenius.com Job Checkin

Arrived for super tune up Filters recently replaced by homeowner Current filters are good Mass build up on both systems indoor coil - reccomended coil clean Mass build up on blower wheel - reccomended blower clean High LRA on both systems - reccomended compressor saver kit or soft start kit Washed outdoor coils and tightened connections Added home and budget plan to non member system and upgraded membership to home and budget on current membership system Systems left on 71 heat at exit


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

Returned and installed filter upgrade. Did a complimentary coil spray and a sanitizing spray. When I left system running and heating.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival system running and cooling producing 16 degree delta with a subcool of 8. Indoor unit clean, coil dirty but otherwise in good shape. Outdoor unit passed all electrical testing. Recommended iaq 1000 electrostatic filter. Pausing call to allow filter to be ordered.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival system running producing a 22 degree delta. System passed all electrical testing outside of the compressor overamping on start up. The systems LRA is 79 and it was pulling 89 today. I recommended a compressor saver to address this and extend the life of the compressor. Compressor saver kits lower the amp draw on start up by 30-40 percent.


Lisa M.

Lisa M. Job Checkin

Completed annual heat and air conditioning tune up.


Brock S.

Brock S. Job Checkin

Arrived for STU All components were working and in tolerance Cap was out of tolerance and refrigerant was low Leak detected and found leak Relayed information to customer Customer did not want to get new coil or replace system at this time. Recommended IAQ 200, compressor saver, cap, line set cover, refrigeran, and membership Customer okayed all recommendations. Installed everything, charged up system and system was running when I left.


Blake  B.

Blake B. Job Checkin

Tech arrived at a service call. Upon inspection, the furnace control board was recieving low voltage but not supplying it. The fan and cooling functioned but not the heat strips as they were not recieving a signal. The blower area was very dirty. The customer was informed of recommendations today. He will not be able to move forward with repairs at this time. The system was not heating upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a membership package unit tune-up. It was raining. Upon inspection, the capacitor tested out of tolerance. The contactor was in working condition. The system did not appear to have Surge Protection. The filter was recently replaced. The blower area had growth present including in the wiring. The blower wheel was dirty. The drain was clear and bleach was poured. The customer was informed of recommendations today. He decided to move forward with replacing the capacitor. This item was replaced tested and functional. The system was returned to the office position upon departure.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival the system was running and cooling producing a 17 degree delta. The coil and drain line were clean and clear. The blower was dirty, and will be cleaned on the level 2 duct cleaning. The outdoor unit passed all electrical tests. I am pausing this call in order for the duct cleaning to be scheduled.


Blake  B.

Blake B. Job Checkin

Tech arrived at a warranty tuneup. Upon inspection, the capacitor was within specs. The contactorless board was in working condition. The condenser coils were hosed off to assist with air flow across the coils. There was no observed surge protection. The filter was clean. The UV bulb was expired. The drain was clear and bleach was poured. The blower area was clean. The Delta was within range. The customer was informed of recommendations today. He decided to move forward with a Copper Membership today. The system was functioning upon departure.


Diego M.

Diego M. Job Checkin

Upon arrival the system was turned off. Turning system on only indoor comes on. Outdoor unit capacitor out of tolerance. Replaced it under p&l. Left system in working condition. Thank you for choosing comfort experts.