1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Job Locations
for weatherford, tx


Map of Weatherford TX
Justin  P.

Justin P.


Job Checkin

2013 Goodman Airhandler Checked and tightened all electrical connections Drain was clear and draining at this time Filter needs changing, customer did not have an extra filter at this time Heat strips are functional and within manufacture range Blower Motor and wheel are in need of a cleaning due to dust, dirt and biological growth build up Evaporator coil is in need of a cleaning due to dust, dirt and biological growth build up UV system is no longer functional 2013 Goodman Heatpump Checked and tightened all electrical connections Dual run cap was within manufactured range Compressor saver is no longer functional Primary electrical unit was acceptable Defrost board was acceptable Refrigerant levels are showing slightly off due to Airhandler cleanliness Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended UV system upgrade, level 2 duct cleaning, unit